OFX controller installation fails on source machine with error "ControllerInstallationNotCompleted".

This document (7008000) is provided subject to the disclaimer at the end of this document.

Environment

PlateSpin Portability Suite
PlateSpin Protect
PlateSpin Migrate
PlateSpin Forge

Situation

This article discusses information about a conversion job failing when installing controller on source machine with the error "Controller installation has not finished in a timely fashion. Possibly because the machine is slow"
 
This issue can also occur if controller installation is attempted as a seperate job via PortabilitySuiteBrowser/PlatespinBrowser. If manual installation of controller is attempted on source after a failed job, it installs the controller fine. Below error is seen in the diagnostics from the failed job:
 
Type                    RequiresUserIntervention
ReportCode        ControllerInstallationNotCompleted
KB Link              
http://support.platespin.com/kb2/login.aspx?errorCodes=ControllerInstallationNotCompleted
Reason               Possibly because the machine is slow.
Message            Controller installation has not finished in a timely fashion. Possibly because the machine is slow.
 

This error occurs due to remote execution of controller installation failing. The underlying reason is unknown but most likely cause is a security policy preventing remote execution. Controller installation files are copied and can be viewed on source machine in "%Windir%\Platespin" directory.

Resolution

Web.config file needs to be edited to disable remote execution service for controller installation. Follow the instructions below to make the change:
  1. Navigate to the ".\Program Files\PlateSpin PortabilitySuite(\Migrate\Protect) Server\Web" directory.
  2. Using a text editor, open the web.config file.
  3. In the web.config file, locate the following entry (located near the end):

    <add key="InstallControllerUsingService" value="true" />
  4. Change the value from "true" to "false". The entry will look as under:

    <add key="InstallControllerUsingService" value="false" />
  5. Save the changes to the web.config file.

This will change the controller installation mechanism from using remote execution service to using local WMI on the source machine.

Disclaimer

This Support Knowledgebase provides a valuable tool for NetIQ/Novell/SUSE customers and parties interested in our products and solutions to acquire information, ideas and learn from one another. Materials are provided for informational, personal or non-commercial use within your organization and are presented "AS IS" WITHOUT WARRANTY OF ANY KIND.