Database Load job AA2000C, XA2000C, or ZAA2000C does not complete. (NETIQKB53305)

  • 7753305
  • 02-Feb-2007
  • 12-Jan-2009

Environment

System Auditing and Reporting (SAR) 

NetIQ Security Solutions for iSeries 8.0

PSAudit 8.0

Situation

Database Load job AA2000C, XA2000C, or ZAA2000C does not complete.

Error: ' MCH3402: Tried to refer to all or part of an object that no longer exists.'

Error: 'MCH1210: Receiver variable too small'

Why doesn't my Database Load run anymore?

Resolution

PTF 1A03009 resolves an issue where the File, Object, and Library Database load fails and returns error MCH3402: Tried to refer to all or part of an object that no longer exists. This error occurs due to operating system changes introduced in the V5R4 release.

For more information about this PTF, or to download this PTF, see https://www.netiq.com/support/iseries/extended/hotfixes.asp



Cause

This error occurs due to operating system changes introduced in the IBM OS V5R4 release.

Additional Information

Formerly known as NETIQKB53305