B.14 Event Source Management-Connectors

 

Below listed are relevant to Event Source Management-Connectors.

B.14.1 Data Received After Timeout

When the File Connector is configured with a DataTimeout greater than 0 in the package.xml file and the DataTimeout period without reading any data and then new data is read from the file, the following internal event is generated.

Table B-121 Event Source Management (Connectors)- Data Received After Timeout

Tag

Value

Severity

4

Event Name

FileUpdatedAfterTimeout

Resource

FileConnector

SubResource

FileConnector

Message

After Event source<File Event Source ID> reached time out of<Timeout Period>, file<File Location> received new data.

B.14.2 Data Timeout

When the File Connector is configured with a DataTimeout greater than 0 in the package.xml file and no data is read from the file in the DataTimeout period, the following internal event is generated.

Table B-122 Event Source Management (Connectors)- Data Timeout

Tag

Value

Severity

4

Event Name

FileTimeout

Resource

FileConnector

SubResource

FileConnector

Message

Event source <File Event Source ID> reached time out of <Timeout Period> when processing file <File Location>.

B.14.3 File Rotation

When the File Connector is configured to use file rotation and the Connector changes from one file to the next, the following internal event is generated.

Table B-123 Event Source Management (Connectors)- File Rotation

Tag

Value

Severity

4

Event Name

RotatingFile

Resource

FileConnector

SubResource

FileConnector

Message

File rotated for event source <File Event Source ID>. Rotating file from <Previous File Location> to <New File Location>.

B.14.4 Process Auto Restart Error

Table B-124 Event Source Management (Connectors)- Process Auto Restart Error

Tag

Value

Severity

4

Event Name

ProcessAutoRestartError

Resource

ProcessConnector

SubResource

ProcessConnector

Message

Process <{0}> [command: {1}] was automatically restarted more than the allowed {2} automatic restart(s) in {3} min. The process will no longer be automatically restarted. Please check process configuration.

B.14.5 Process Start Error

Table B-125 Event Source Management (Connectors)- Process Start Error

Tag

Value

Severity

1

Event Name

ProcessStartError

Resource

ProcessConnector

SubResource

ProcessConnector

Message

Error starting command: {0}

B.14.6 Process Stop

Table B-126 Event Source Management (Connectors) - Process Stop

Tag

Value

Severity

1

Event Name

ProcessStop

Resource

ProcessConnector

SubResource

ProcessConnector

Message

Process <{0}> exited [command: {1}]

B.14.7 WMI Connector Status Message

Table B-127 Event Source Management (Connectors) - WMI Connector Status Message

Tag

Value

Severity

4

Event Name

WMIConnectorStatusMessage

Resource

WMIConnector

SubResource

WMIConnector

Message

<Exception>