5.12 Voltage

Use this Knowledge Script to monitor the server voltage probe on Dell computers running Linux. This script raises an event if the voltage probe status is other than OK and when the voltage probe reading falls outside system-defined thresholds or the thresholds you set.

For information about voltage probe object properties, see Section 5.1.9, Voltage Properties.

This Knowledge Script requires OMSA components on the Dell computer you are monitoring. You can install these components using the srvadmin-all meta package.

5.12.1 Resource Objects

Voltage probe on a Dell computer running Linux

5.12.2 Default Schedule

The default interval for this script is Every 5 minutes.

5.12.3 Setting Parameter Values

Set the following parameters as needed:

Description

How to Set It

Event Settings

Raise event if voltage probe status is not OK?

Set to Yes to raise an event if the voltage probe has a status value other than OK. The default is yes.

Event severity

Specify the event severity level, from 1 to 40, to indicate the importance of an event in which the voltage probe status is other than OK. The default is 5.

Raise event if voltage probe reading is not good?

Set to Yes to raise an event if the voltage probe reading is not good. The default is yes.

Event severity

Specify the event severity level, from 1 to 40, to indicate the importance of an event AppManager reports when the voltage probe reading is not good. The default is 5.

Raise event if voltage probe reading exceeds threshold?

Set to Yes to raise an event if the voltage probe reading exceeds the threshold value you set. The default is yes.

Threshold value (in Volts)

Set the maximum acceptable voltage probe reading in Volts. If enabled, this job will raise an event when the voltage probe reading exceeds this value. The default is 2.5.

Event severity

Specify the event severity level, from 1 to 40, to indicate the importance of an event where the voltage probe reading exceeds the threshold you set. The default is 5.

Raise event if voltage probe reading is out of system configured range?

Minimum warning threshold - Maximum warning threshold range?

Set to Yes to raise an event if the voltage probe reading is outside the range defined by the minimum and maximum warning threshold values. The default is no.

Minimum failure threshold - Maximum failure threshold range?

Set to Yes to raise an event if the voltage probe reading is outside the range defined by the minimum and maximum failure threshold values. The default is no.

Event severity

Specify the event severity level, from 1 to 40, to indicate the importance of an event where the voltage probe reading is outside the warning and/or failure threshold range. The default is 5.

Raise event if AppManager fails to get metrics?

Set to Yes to raise an event when AppManager fails to collect any information about the voltage probe. The default is yes.

Event severity

Specify the event severity level, from 1 to 40, to indicate the importance of an event where AppManager fails to get any information about the voltage probe. The default is 5.

Event severity when job fails

Specify the event severity level, from 1 to 40, to indicate the importance of an event where this job fails.The default is 5.

Data Collection

Collect data for voltage probe reading?

Set to Yes to collect data for the chassis voltage probe. By default, the data is not collected.