Use this Knowledge Script to monitor the status of the array physical drives on Dell servers. This Knowledge Script raises an event if the drive is not operational. The Dell server defines the characteristics of normal operation, degraded operation, and physical drive failure.
Array Physical Drive icon
The default interval is Every 10 minutes.
Set the following parameters as needed.
Description |
How To Set It |
---|---|
Event? |
Set to y to raise events. The default is y. |
Collect data? |
Set to y to collect data for charts and reports. If set to y, this Knowledge Script returns:
The default is n. |
Community |
Set the community string in Security Manager for Dell OpenManage server Agent or Dell-iDRAC resources:
|
Raise only one event if SNMP down? |
Set to y to raise only a single event rather than an event for each monitored object when the SNMP service is down. The default is y. |
Event severity for SNMP or Dell Managed Node failure |
Set the event severity, from 1 to 40, to indicate the importance of an event in which the SNMP service or Dell Managed Node fails. The default is 10. |
Event severity when SNMP restored |
Set the event severity, from 1 to 40, to indicate the importance of an event in which the SNMP service has been restored. The default is 30. |
Event severity when array physical drive failure |
Set the event severity, from 1 to 40, to indicate the importance of an event in which the array physical drive fails. The default is 10. |
Event severity when array physical drive degraded condition |
Set the event severity, from 1 to 40, to indicate the importance of an event in which the array physical drive is in a degraded condition. The default is 20 |
Event severity when array physical drive removed |
Set the event severity, from 1 to 40, to indicate the importance of an event in which the array physical drive has been removed. The default is 15. |
Event severity when array physical drive rebuilding or recovering |
Set the event severity, from 1 to 40, to indicate the importance of an event in which the array physical drive is rebuilding or recovering. The default is 25. |
Event severity when array physical drive offline |
Set the event severity, from 1 to 40, to indicate the importance of an event in which the array physical drive is offline. The default is 25. |